초록

In order to clarify the characteristics of power performance and uncertainty of a wind turbine, an investigation was performed in Hangyeong wind farm, Jeju island, Korea. Data were collected for 12 months from Feb. 2, 2008 to Jan. 1, 2009. This study was conducted on the base of the International standard, and observed the methods of mesurement and evaluation form IEC 61400-12. As a result, power performance curve was calculated by measured data and compared with the sixth unit of VESTAS V90-3.0MW in Hangyeong wind farms. In consequence of this paper, uncertainty was estimated from 7% to 14% on the range of the average wind speed from 4m/s to 11m/s.

키워드