구조 변경을 통한 공조용 압축기의 소음저감
Noise Reduce in the Rotary Compressor for air-conditioner using Structural Modification
초록
The main noise source of the rotary compressor for air conditioner was analyzed by using the measurement of sound intensity, modal analysis and operational deflection shape(ODS) analysis. In this study, the key noise source of rotary compressor was an accumulator, and noise was sharply increased due to the accumulator's resonance which has a big contribution to the noise. To reduce the excessive noise generated from accumulator, structural modification through ODS analysis were applied. Its validation was conducted by the measurement of noise and vibration on the accumulator's surface. The total noise was significantly reduced by 4.2dB(A).