Abstract

With the development of wind industry, the rated power of wind turbine also increase gradually. Accordingly, the size of wind turbine tower becomes larger and larger. The tower base diameter of 2MW wind turbine is about 4m. Larger tower is expected for 4MW or 5MW turbine. Due to limitation of transportation, new type of tower with smooth transportation and effective cost is needed. In this work, a hybrid tower consisting of steel and concrete is designed and analyzed. The optimum ratio of steel and concrete of hybrid tower are calculated as well as the thickness of the concrete part. Different FE analysis including modal analysis, buckling analysis and fatigue analysis are performed to check the design of hybrid tower comparing with the steel tower. Redesign is also expected after various analysis.