Review for C/H Bulkhead Stringer with Opening

6,500 TEU Container 선박의 Opening을 고려한 Cargo Hold Bulkhead Stringer 구조의 Strength 검토

  • Ha, Ji-Hyung (Hanjin Heavy Industries & Construction Co.,LTD) ;
  • Park, Dong-Kun (Hanjin Heavy Industries & Construction Co.,LTD) ;
  • Kim, Bo-Eun (Hanjin Heavy Industries & Construction Co.,LTD) ;
  • Jeon, Ji-Yoon (Hanjin Heavy Industries & Construction Co.,LTD)
  • 하지형 ((주)한진중공업 선체기본설계팀) ;
  • 박동근 ((주)한진중공업 선체기본설계팀) ;
  • 김보언 ((주)한진중공업 선체기본설계팀) ;
  • 전지윤 ((주)한진중공업 선체기본설계팀)
  • Published : 2009.09.30

Abstract

Openings for access to cargo holds are cut on horizontal stringers in every bulkhead of container carriers. But, they are positioned at the edge of stringer width to make minimum space for access and these openings are required to be stiffened by owners and classifications respectively. In this paper, the cargo hold bulkhead stringers with openings for 6,500 TUE container carriers were reviewed by FE analysis to be conducted with the results of hold analysis for 6,500 TUE container carriers classed to GL, DNV, LR and BV respectively, and purpose of this paper is to establish yard's standard of the reinforcement for these openings.

Keywords