Mock-Up Test for the Fire Resistance Analysis of High Strength RC Beam and Slab Using the Polylon Fiber
폴리론 화이버를 혼입한 고강도 RC 보 및 슬래브의 내화특성 분석을 위한 Mock-Up 실험
- Son, Ho Jung ;
- Hwang, Dong Gyu ;
- Hann, Chang Pyung ;
- Han, Min Cheol ;
- Yang, Seong Hwan ;
- Han, Cheon Goo
- 손호정 (청주대 대학원) ;
- 황동규 (두산건설(주) 기술연구소) ;
- 한창평 ((주)휴다임건축사사무소) ;
- 한민철 (청주대 건축공학부) ;
- 양성환 (인천전문대학 건축과) ;
- 한천구 (청주대 건축공학부)
- Published : 2009.11.14
Abstract
The objective of this study is to analyze the insulation characteristics of the polylon hybrid fiber inserted high-strength RC beam and slab produced as a single body and the results of this study can be summarized as follows. In the spalling mechanism as an insulation characteristic, the slab of the single body type specimen shows an exposure in concrete covers at the center of slab and that leads to the spalling, which exposures reinforcing bars. In the case of the beam, the spalling was presented at several sections as a type of peel spalling before and after 10 minutes from the insulation test. Whereas, although the internal temperature history of concrete represents the highest range as 581℃ in the case of the center of the bottom of beam base, it can be considered that it satisfies the regulation of insulation certification.
Keywords