Characteristics of integral imaging microscope using point light source array
- Lim, Young-Tae (College of Electrical & Computer Engineering, Chungbuk National University) ;
- Park, Jae-Hyeung (College of Electrical & Computer Engineering, Chungbuk National University) ;
- Kwon, Ki-Chul (College of Electrical & Computer Engineering, Chungbuk National University) ;
- Kim, Nam (College of Electrical & Computer Engineering, Chungbuk National University)
- Published : 2009.10.12
Abstract
In this paper, we explained characteristics of integral imaging microscope using point light source. To display the bio-medical information, which is captured as a form of the elemental images, using autostereoscopic displays, the characteristics analysis of three-dimensional information is required. For integral imaging microscope using point light source array, the elemental image capturing configuration has to satisfy a specific condition. We explain the condition to capture the elemental images and show the experimental results.