Proceedings of the KSR Conference (한국철도학회:학술대회논문집)
- 2009.05a
- /
- Pages.433-441
- /
- 2009
A Study on Analysis of Impulse Track Circuit using PSCAD/EMTDC
PSCAD/EMTDC를 이용한 임펄스 궤도회로의 계통분석 연구
- Published : 2009.05.21
Abstract
We have studied a weird phenomenon on the High Voltage Impulse Track Circuit (HVITC). The biggest problem is that can not recognize the fault states, despite the fact the rail is broken. This study has shown that current HVITC systems can be operated even an ill-contact state of impedance bond lead wire. This study was carried out using various methods, such as measurements using an oscilloscope with voltage and current probes, simulations using PSCAD/EMTDC software tool, and analysis of measured data. Especially, we have simulated the fault state through bypass circuits using PSCAD/EMTDC software tool. We made a model of track circuit and simulated various types of fault states.
Keywords