Proceedings of the Korean Society of Propulsion Engineers Conference (한국추진공학회:학술대회논문집)
- 2009.11a
- /
- Pages.273-277
- /
- 2009
- /
- 1975-342X(pISSN)
Performance Test of an Oxidizer Tunnel-Type Pipe for Launch Vehicle
발사체 산화제 터널형 배관 성능시험
Abstract
An oxidizer tunnel-type pipe, which shall transport oxidizer from an oxidizer tank to a turbo-pump of an engine, studied is installed through a fuel tank located under an oxidizer tank. A tunnel-type pipe can save weight compared to a detour-type pipe, however may vary the temperature of fuel stored in a fuel tank because of a broad heat transfer area. Hence in this study the characteristics of main oxidizer pipe and thermal propagation from oxidizer to a fuel tank are monitored by a cryogenic performance test with a tunnel-type pipe. In addition, the possibility of adaptation of an oxidizer tunnel-type pipe to launcher system is also analyzed.
본 연구에서 적용한 발사체용 산화제 터널형 배관은 액체산소를 터보펌프까지 전달하는 장치로 산화제 탱크 하부에 설치된 연료탱크를 관통하여 설치된다. 터널형 배관은 연료탱크를 우회하여 설치되는 우회 배관에 비해 무게가 절감되나 열전달 표면적이 커져 연료 탱크에 저장된 연료의 온도를 변화 시킬 수 있다. 따라서 본 연구에서는 터널형 배관의 극저온 성능시험을 통하여 배관 특성 및 연료 탱크로의 열전달 현상을 고찰하였으며, 또한 발사체에 적용가능성을 확인하였다.
Keywords