1Monitoring system for the subway structures using pre-strain controllable FBG sensors

프리스트레인 가변형 광섬유센서를 이용한 지하철 구조 모니터링시스템

  • Kim, Ki-Soo (Dept. of Materials Science and Engineering, Hongik University)
  • Published : 2009.09.25

Abstract

FBG sensor system is applied to the concrete lining structure in Taegu subway. Near the structure, the power cable tunnel construction started. We wanted to measure the deformation of the structure due to the construction by the FBG sensor. The applied sensor has the gauge length of 1 meter to overcome the inhomogeneity of the concrete material with enough length. In order to fix tightly to the structure, the partially stripped parts of the sensor glued to the package and slip phenomenon between fiber and acrylate jacket was prevented. Prestrain of the sensor was imposed by controlling the two fixed points with bolts and nuts in order to measure compressive strain as well as tensile strain. The behavior of subway lining structure could be monitored very well.

Keywords