Investigation on the Self-Pressurization in Cryogenic Liquid Storage System
극저온 유체 저장 시스템의 압력 증가에 대한 연구
- Published : 2008.06.25
Abstract
This paper reports an analysis of self-pressurization in a closed cryogenic liquid storage system and its comparison with experimental data using liquid nitrogen. Partial equilibrium model(PEM), revised thermodynamic analysis of homogeneous model, has been applied for the pressurization in a closed tank. The vapor and liquid bulk temperature and the liquid-vapor interface temperature are separately calculated as their own representative values in this analysis. The analysis results of the partial equilibrium model are compared with the experimental data and other preceding homogeneous temperature models for validation.
Keywords