Effective Dynamic Models of a Cooling System for the Main Transformer in a Tilting Train

틸팅열차 주변압기 냉각시스템의 동적모델

  • 한도영 (국민대학교 기계.자동차공학부) ;
  • 노희전 (국민대학교 기계공학과 대학원) ;
  • 원재영 (국민대학교 기계공학과 대학원)
  • Published : 2008.06.25

Abstract

In order to improve the efficiency of a main transformer in a tilting train, the optimal operation of a cooling system is necessary. For the development of optimal control algorithms of a cooling system, mathematical models of a main transformer cooling system were developed. These include dynamic models of a main transformer, an oil pump, an oil cooler, a blower, and a pipe. Control algorithms for a blower and an oil pump were selected in order to identify the effectiveness of dynamic models. A simulation program was developed by using the developed dynamic models and the selected control algorithms. Simulation results showed good predictions of dynamic behaviors of a main transformer cooling system. Therefore, dynamic models, which were developed in this study, may be effectively used to develop control algorithms of a main transformer cooling system.

Keywords