Concrete Test for Creep and Shrinkage Properties on High Strength Concrete

고강도 콘크리트 크리프 및 건조수축 특성을 위한 재료실험

  • 차한일 (롯데건설(주) 기술연구소) ;
  • 문형재 (롯데건설(주) 기술연구소) ;
  • 석원균 (롯데건설(주) 기술연구소) ;
  • 박순전 (롯데건설(주) 기술연구소)
  • Published : 2008.04.24

Abstract

This study shows systematic procedures for investigating creep and shrinkage properties of 50, 60, 70 MPa concrete mixes, which were developed by Lotte E&C R&D Ins. for Lotte Super Tower Jamsil. The concrete test was performed both local and foreign laboratory, S-Lab. and CTL Group respectively. The former have done for total five days. The procedures included the followings, specimen fabrication, mold removal, specimen marking, water bath curing, packaging, and shipment. The latter has been doing by CTL within PCA(Portland Cement Association). They are testing on static and dynamic modulus of elasticity, compressive strength, creep & shrinkage, splitting tensile strength. In the case of creep and shrinkage, the test will be doing for 18 months according to each loading age.

본 연구는 잠실제2롯데월드에 적용된 50, 60, 70MPa 콘크리트 강도에 대한 크리프 및 건조수축 특성 파악을 위한 재료연구의 일환으로 진행된 콘크리트 테스트 프로그램의 준비 단계에 대한 일련의 체계화된 과정을 나타내고 있다. 콘크리트 테스트 프로그램의 준비단계는 국내와 국외에서 진행되었다. S사 실험실에서 진행된 국내 진행일정은 총 5일간 진행되었으며 그 진행과정은 공시체 제작, 몰드탈형, 공시체 마킹, 수중양생, 포장, 및 운송으로 이루어져 있다. 국외에서는 PCA(Portland Cement Association)산하 CTL사에서 진행되고 있으며 테스트 항목은 탄성계수 측정테스트(정탄성 & 동탄성), 압축강도 테스트, 크리프 건조수축 테스트, 및 할렬인장강도 테스트가 진행되고 있다. 크리프 및 건조수축 실험의 경우에는 하중 재령일에 따라 총 18개월간 테스트가 진행될 예정이다.

Keywords