Static Behavior of Bi Prestressed Concrete Girders

프리스트레스트 콘크리트거더의 정적거동 평가

  • Published : 2008.04.24

Abstract

This study was performed to estimate the workability and the static behavior for Bi Prestressed Concrete Girder(Bicon girder) which could introduce effectively prestressed forces into concrete girders. A bicon girder is manufactured by means of introducing pure bending moment that prestress simultaneously the compressive member(steel bar) and the tensile member(steel tendon). Static test was executed for 20m railway bridge girder specimen and evaluated whether pure bending moment was introduced or not, and the behaviors after cracking, and at the ultimate load. Test results showed that a bicon girder had the enough safety in the introduction of pure moment, the serviceability, and the ultimate behavior.

이 연구에서는 저형고의 콘크리트거더에 효율적으로 프리스트레스를 도입할 수 있는 Bi Prestressed Concrete Girder(이하 Bicon거더)에 대한 정적 구조성능을 검증하였다. Bicon거더는 거더 상연에 강봉(압축재)와 하연에 강연선(인장재)를 동시에 긴장하여 두 부재의 편심을 이용, 부재에 순수한 휨만을 도입할 수 있는 프리스트레싱 공법으로 제작된다. 구조성능검증을 위해 철도 LS-22하중으로 20m Bicon거더 시험체를 제작하였다. 프리스트레스 도입시 콘크리트 부재에 순수 휨의 도입여부를 계측하였고, 탄성 및 균열 후 거동, 파괴시의 극한거동을 평가하기 위해 정적 재하시험을 수행하였다. 시험결과 긴장시 중앙단면의 효과적인 휨모멘트의 도입을 확인하였고, 정적하중 재하시 균열은 사용하중의 약 1.2배의 하중에서 발생하였으며 극한강도는 최대저항모멘트보다 15% 이상 증가되는 결과를 보여 충분한 안전율을 갖고 있는 교량거더로 평가되었다.

Keywords