This paper proposes a method to predict the ductility capacity of reinforced concrete beam-column joints failing in shear after the formations of plastic hinges at both ends of the adjacent beams. The current design code divides joints into two categories: Type 1 for structures in non seismically hazard area and Type 2 in seismically hazard area. While there are many researches related to joint shear strength in Type 1, those in regard to joint ductility capacity of Type 2 are scarce. This paper classified the ductility capacity of beam-column joints into column, joint panel, and beam deformability. Since a brittle failure such as shear or bond failure in the columns must be avoided, column deformability was calculated by elastic analysis. The plastic hinges of the adjacent beams affect joint deformability. Therefore, the prediction of joint deformability was calculated with consideration to the degradation of the diagonally compressed concrete due to the strain penetration.

이 연구에서는 지진하중을 받는 철근콘크리트 보-기둥 접합부의 연성능력을 평가하였다. 철근콘크리트 보-기둥 접합부 설계는 보에 소성힌지가 발생하기 이전에 접합부가 파괴하는 경우와 보에 소성힌지가 발생한 이후에 접합부 또는 보가 파괴하는 경우로 구분하여 설계하고 있다. 지금까지의 대부분의 기존 연구는 접합부의 강도 평가에 중점을 두고 있으며, 접합부의 연성능력 평가에 대한 연구는 미흡한 실정이다. 이 연구에서는 접합부의 연성을 기둥, 보, 접합부 패널 부분으로 구분하여 각각의 부재가 보-기둥 접합부의 전체 연성에 미치는 영향을 평가하였다. 접합부 설계는 일반적으로 보에 소성힌지를 발생시키고 접합부를 포함한 기둥은 탄성 상태로 설계하므로 탄성해석에 의하여 기둥의 연성을 평가하였다. 접합부 패널은 보의 소성힌지의 변형에 의하여 영향을 받게 된다. 따라서 이 연구에서는 보의 소성힌지의 영향을 고려한 접합부 패널 연성을 평가하였다. 소성힌지가 발생한 보의 연성은 보-기둥 접합부의 연성능력에 가장 큰 영향을 미친다. 보의 연성은 보의 휨에 의한 영향, 철근의 뽑힘에 의한 영향, 소성힌지 구역의 축방향 변형률 증대에 의한 영향으로 구분하였다. 또한 접합부의 부착강도 저감 및 보의 주철근 항복 이후의 철근의 뽑힘 및 소성힌지 구역의 축방향 변형률 증대에 의한 영향을 고려하여 보의 연성능력을 평가하였다.

Keywords