Influence of Reinforcement Ratio on the Hysteratic Behavior of Rectangle Column-Slab Connection

장방형 기둥-슬래브 접합부의 이력거동에 대한 철근비의 영향

  • Published : 2008.04.24

Abstract

In this investigation, results of laboratory tests on six reinforce concrete flat plate interior connections with elongated rectangular column support which has been used widely in tall residential buildings are presented. The purpose of this study is to evaluate an effect of column aspect ratio(${\beta}$c=$c_1/c_2$) on the hysteretic behavior under earthquake type loading. The aspect ratio of column section was taken as 0.33${\sim}$3($c_1/c_2$=1/3, 1/1, 3/1). Other design parameters such as flexural reinforcement ratio of slab and concrete strength was kept constant as ${\rho}$=1.0%, 1.5% and $f){ck}$=40MPa, respectively. Gravity shear load($V_g$) was applied by 30 percents of nominal vertical shear strength(0.3$V_o$) of the specimen. Experimental observations on punching failure pattern, peak lateral-load and story drift ratio at punching failure, and stiffness degradation were achieved and discussed in accordance with different column aspect ratio.

본 연구는 주거용 고층 건물에서 폭넓게 사용되고 있는 플랫 플레이트 구조에서 장방형 기둥-슬래브 접합부를 대상으로 실시한 6개의 실험결과를 분석한 것이다. 연구의 목적은 지진하중과 같이 반복적으로 작용하는 횡하중에 대하여 기둥 단면의 형상비(${\beta}$c=$c_1/c_2$)에 따른 접합부의 이력거동을 비교 평가 하는 것이다. 기둥 형상비는 $b_o$가 일정해 지도록 0.33${\sim}$3($c_1/c_2$=1/3, 1/1, 3/1)으로 선정하였다. 슬래브 휨철근비는 1.0%, 1.5%로 변화시켰으며, 중력전단력비($V_g/V_c$) 등 접합부의 이력거동에 영향을 줄 수 있는 다른 영향인자들은 일정한 조건으로 계획하여 기둥 형상비의 영향을 고찰할 수 있도록 하였다. 실험을 통해서 뚫림전단파괴 양상과 균열 패턴, 접합부의 강성, 변형능력 등을 변수에 따라 분석하였다.

Keywords