Abstract
This study evaluated fire resistance performance for polypropylene/steel fiber reinforced high strength concrete column. Full-size columns were constructed and tested with or without fibers using ISO-834 fire curve. As the result of test, non-fiber high strength concrete column specimen occurred serious spalling and indicated rapidly internal temperature increase. Specimen with polypropylene fiber occurred not spalling. Specimen with hybrid fiber occurred not spalling as well as does not propagated temperature propagation. Therefore, hybrid fiber reinforced column specimen indicated a good fire resistance performance than other cases.
본 연구에서는 폴리프로필렌섬유와 강섬유 혼입에 따른 고강도 기둥 콘크리트의 내화특성을 평가하였으며 내화특성 평가를 위하여 ISO-834 곡선을 적용하여 내화실험을 실시하였다. 실험결과 섬유보강재를 혼입하지 않은 기둥 시험체의 경우 폭렬이 심하게 발생하였으며 높은 내부온도를 나타났다. 폴리프로필렌섬유를 혼입한 고강도 콘크리트 기둥 시험체의 경우 폭렬이 발생하지 않았으며 내부온도 결과에 있어서도 섬유보강재를 혼입하지 않은 경우보다 낮게 나타났다. 폴리프로필렌섬유와 강섬유를 혼입한 기둥 공시체의 경우 폭렬이 발생하지 않았으며 가장 낮은 내부온도를 나타내 가장 우수한 내화성능을 나타냈다.