Proceedings of the Korea Concrete Institute Conference (한국콘크리트학회:학술대회논문집)
- 2008.11a
- /
- Pages.301-304
- /
- 2008
An Experimental Study on Steel Plate Coupling Beam
철골 플레이트 커플링 보의 실험적 연구
Abstract
This paper presented an structural efficiency of steel coupling beam jointed single plate shear connections with seat and top angle. Parameters for the test specimens were are seat and top angle, reinforcing of concrete, embedded length, section loss. Steel coupling beam with angle showed excellent strength, stiffness, energy dissipation capacity. The specimen with no reinforcement around the embedded steel plate showed slightly low deformation capacity because of early failure in the precast concrete walls. However, the specimen with reinforcement around the embedded steel plate showed good deformation capacity. Deformation capacity was not decrease despite short embedded length. The specimen with section loss showed excellent deformation capacity. Because shear strength of steel coupling beam was lesser than of connections. These results showed that for workability and cost efficiency, the proposed system is promising for one of steel coupling beam.
본 연구에서는 싱글 플레이트 전단접합에 앵글을 접합한 새로운 방식의 철골 커플링보를 개발하여 여러 가지 구조적 성능을 평가하고자 한다. 주요 변수는 앵글유무, 콘크리트 보강 유무, 매립길이, 결손단면이다. 실험은 커플링 보의 가운데 지점을 2,000kN Actuator를 이용하여 횡방향 반복가력을 가하여 구조물의 전체적인 거동을 알아본다. 실험결과 싱글 플레이트 전단 접합부로 이루어진 실험체보다 앵글을 접합한 실험체가 강도, 변형능력, 강성, 에너지 소산 능력 등 전반적인 구조적 성능이 훨씬 우수한 것으로 나타났다. 매립된 철골보 주위에 전단철근을 보강하지 않은 경우 PC벽체의 조기 지압파괴로 인해 그 성능이 현저히 떨어지는 것으로 나타났다. 그러나 전단철근이 배근이 된 경우 철골 커플링 보의 전단 항복이 발생할 때까지 PC벽체의 파괴가 충분히 지연되는 것으로 나타났다. 앵글이 접합된 경우 매립길이가 작아도 그 성능이 떨어지지 않았다. 결손 단면이 있을 경우 강도는 작게 나타났으나 접합부 전단 강도보다 훨씬 작도록 설계된 관계로 PC벽체의 파괴가 발생하기 전에 충분히 전단 거동을 통해 우수한 성능을 발휘하였다. 이러한 결과는 시공성과 경제성 향상을 위해 앵글을 접합한 철골 커플링 보 방식이 매우 유용할 것으로 사료된다.
Keywords