This study has explained about LED for BLU which is widely used in the kinds of display devices or lighting. It was shown that the open due to delamination were the dominant LED for BLU failure mode and mechanisms from failure analysis of LED samples. Then, we have defined failure as yellowing and 100% reduction of light output intensity of LED for BLU and acceleration factors as temperature and current in Accelerated Life Test(ALT). Finally, we have estimated the Weibull distribution, life-stress relationship, and accelerating factor is used by ALTA Software.