Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference (한국조명전기설비학회:학술대회논문집)
- 2007.11a
- /
- Pages.9-10
- /
- 2007
The Classification of EOLL (End of Lamp Life) on fluorescent lamp and Detection Method
형광 램프 수명 말기에 대한 구분과 검출 방법
Abstract
This paper presents that what's the right EOLL(End of Lamp Life) phenomenon on fluorescent lamp and how to detect it according to the lamp status. In normal end of life situation for fluorescent lamps is emitter depletion of the cathodes. So, in most cases, the discharge will extinguish and the lamp will not start. But if the ballast is capable of sustaining the discharge, a new condition arise. Especially, the T4 and T5 lamp which has a short distance from cathode to socket of lamp future must have the EOLL Protection function.
Keywords