세라믹필터 역세정을 위한 노즐 사이즈 최적화

The optimization of nozzle size for pulse cleaning of ceramic filter

  • 최주홍 (생명화학공학과, 경상대학교) ;
  • 김진형 (생명화학공학과, 경상대학교) ;
  • 지화창 (생명화학공학과, 경상대학교) ;
  • 우량 (생명화학공학과, 경상대학교) ;
  • 사공경민 (생명화학공학과, 경상대학교) ;
  • 김영애 (생명화학공학과, 경상대학교)
  • 발행 : 2007.06.21

초록

In the bench scale test unit consisting of four commercial filter elements, the traces of the transient pressure around the nozzle and overpressure in the filter cavity were measured to estimate the effect of nozzle on pulse cleaning. For the given pulse cleaning system, the convergent nozzle displayed better performance than the straight one. The optimum ratio of outlet to inside diameter of convergent nozzle was determined, which minimized the pulse gas consumption and maximized the entrainment effect. The angle and height of nozzle convergent part was also optimum operational condition, which is meaningful to the industrial applying.