The Estimation of Bearing Capacity of Auger-drilled Pile in Sand-Gravel by Dynamic Load Test

동재하시험에 의한 모래자갈층에 근입된 매입말뚝의 지지력 산정

  • 최기철 (한양대학교 대학원 토목공학과) ;
  • 문유호 ((주)지오사이트) ;
  • 오원근 (한양대학교 대학원 토목공학과) ;
  • 천병식 (한양대학교 토목공학과)
  • Published : 2007.05.17

Abstract

This study results of performed field load test in order to estimate the best pile length assessment and allowable bearing capacity of the pile foundation. End of initial driving(EOID) and restrike of pile dynamic loading tests were performed to calculate allowable bearing capacity of the experimental pile side and results were compared with the allowable bearing capacity estimated by theory. The results of allowable bearing capacity by EOID test is $1.08{\sim}1.21$ in the range of compared to the capacity calculated by the Structure Foundation Design Criterion. Allowable bearing Capacity by restrike of pile dynamic loading test is $1.32{\sim}1.48$ in the range of compared to the Structure Foundation Design Criterion. The Foundation Design Criterion underestimated the pile capacity. If the bearing capacity calculated by Structure Foundation Design Criterion is 100, EOID of pile dynamic loading test is 116, restrike of pile dynamic loading test is 138 for 20m pile used in this experimental.

Keywords