Improve the Gamma variation by monitoring the angle of the polarizer absorption axis

  • Published : 2007.08.27

Abstract

Gamma curve is one of the most important optical performance characteristics of a liquid crystal display. we present investigations on the relationship between gamma and polarizer. The gamma curve is affected by the angle of the polarizer absorption axis. When the crossed angle between the two polarizers turns larger, gamma values will decrease. The gamma variation caused from each polarizer variation could be improved by monitoring and controlling the axial direction of the polarizers.