Experimental Study on the Thermal Mixing and the Critical Heat Flux in the 5${\times}$5 Rod Bundle with the Hybrid Mixing Vane

복합혼합날개를 장착한 5${\times}$5 봉다발에서 부수로 혼합 및 임계열유속 실험 연구

  • 강경호 (한국원자력연구원 열수력안전연구센터) ;
  • 신창환 (한국원자력연구원 열수력안전연구센터) ;
  • 추연준 (한국원자력연구원 열수력안전연구센터) ;
  • 윤영중 (한국원자력연구원 열수력안전연구센터) ;
  • 박종국 (한국원자력연구원 열수력안전연구센터) ;
  • 문상기 (한국원자력연구원 열수력안전연구센터) ;
  • 천세영 (한국원자력연구원 열수력안전연구센터)
  • Published : 2007.05.30

Abstract

Experiments were performed to determine the thermal (or turbulent) diffusion coefficient (TDC) and to investigate the critical heat flux (CHF) performance in the 5${\times}$5 rod bundle with 5 unheated rods which are supported by Hybrid Mixing Vane. In this study, HFC-134a fluid was used as working fluid and the fluid temperature were measured in the important subchannels. To determine the TDC value, the measured fluid temperatures were compared with the predicted values obtained from the MATRA code. The best optimized value of ${\beta}$ was found to be 0.02 by considering prediction statistics, i.e., average and standard deviations of the differences between the experimental results and code calculations. Using the best optimized value of ${\beta}$ as 0.02, the MATRA code predicts the test results of the fluid temperature within ${\pm}$1.0 % of error. According to the experimental results on CHF of 5 non-heating guide tubes, the case with non-heating guide tube showed a little good performance in terms of CHF.

Keywords