Response of Annoyance for Impulsive Noise - Focusing on the Construction Noise -

충격성 소음에 대한 성가심 반응 - 건설공사장 소음을 중심으로 -

  • 김득성 (서울시립대학교 환경공학과 대학원) ;
  • 장서일 (서울시립대학교 환경공학부) ;
  • 전형준 (서울시립대학교 환경공학과 대학원) ;
  • 이연수 (서울시보건환경연구원)
  • Published : 2007.11.15

Abstract

This research presents a laboratory study about an annoyance of impulsive sound caused by construction site(breaker and blasting). The sources are sampled from outdoor noise and their levels range from 40 to 75 dB at the interval of 5dB. The noise unit is based on A-weighted sound exposure level (ASEL; $L_{AE}$). To make equal ASEL of outdoor noise, finite impulse response (FIR) filter is applied to the originally sampled source to include the effect of distance attenuation. The evaluation method of jury test adopted a Semantic Difference Method (SDM). In the result of the Jury test for impulsive noise, the annoyance response of blasting noise was higher than that of breaker noise.

Keywords