Implementation of an Over-Current Relaying Algorithm Using 80C196KC

80C196KC를 이용한 과전류 계전 알고리즘 구현

  • Kim, Hyung-Kyu (Next-generation Power Technology Center, Myongji University) ;
  • Lee, Bong-Hyun (Next-generation Power Technology Center, Myongji University) ;
  • Kang, Sang-Hee (Next-generation Power Technology Center, Myongji University)
  • 김형규 (명지대학교 차세대전력기술연구센터) ;
  • 이봉현 (명지대학교 차세대전력기술연구센터) ;
  • 강상희 (명지대학교 차세대전력기술연구센터)
  • Published : 2007.07.18

Abstract

An Over Current Relayng algorithm using 80c196kc micro processor was realized in this paper. This OCR Algorithm was verified with simulated fault signal. The fault signal was made by EMTP and realized by DOBLE to compare H/W test with S/W test. This simulations showed similar result between H/W and S/W test.

Keywords