재건축현장 철근탐사 검사장비의 정확도 평가

Assessment of Accuracy for the Rebar Detecting Device at Reconstruction Site

  • 박성모 (연세대학교 건축공학과) ;
  • 임홍철 (연세대학교 건축공학과) ;
  • 임병호 (GS건설(주) 연구개발팀)
  • 발행 : 2006.05.01

초록

The purpose of the research is to assess the accuracy of steel bar detector among other nondestructive testing equipment. The result of previous research shows that the average errors of rebar detector are 14.7% for the cover depth, 2.3% for the rebar spacing, and 11% for the rebar diameter. But this experiment was performed at the laboratory and the mortar was used for covering the steel bars instead of concrete. In situ condition can be different from the laboratory's so the outcomes do not correspond with those of laboratory. This research was performed at the buildings to be reconstructed. Nondestructive and destructive testing can be performed side by side since the building if to be destroyed. Steel bar detector was operated on the beam and the column and concrete cover of those members was removed for the actual measurement of rebar depth, spacing, and diameter finally, presumed value can be directly compared with actual data.

키워드