This paper is to investigate passing performance of high performance concrete between reinforcing bar depending on maximum size of coarse aggregates. Increase in maximum size of coarse results in decrease in water demand and sand to aggregate to secure target slump flow. The larger the maximum size of coarse aggregates is, the denser the space between reinforcing bar is, the amount of concrete passed through the reinforcing bar cage shows to decrease. HPC has favorable passing performance, regardless of aggregate size, when only vertical reinforcing bar is arranged. Whereas, when vertical and horizontal reinforcing bar is arranged at the same time, proper space between reinforcing bar is considered larger than 32mm in case of using 20mm coarse aggregate, 38mm in case of using 25mm aggregate. The increase in maximum size of coarse aggregate leads to increase compressive strength slightly. Length change shows to be decreased with the increase in maximum size of coarse aggregate.