Proceedings of the Korea Concrete Institute Conference (한국콘크리트학회:학술대회논문집)
- 2006.05b
- /
- Pages.73-76
- /
- 2006
An Exposure Experiment for the Evaluation of Corrosion Properties of Sewage Concrete Covered with Antibiotics
항균제를 도포한 하수시설 콘크리트의 생화학적 부식특성 평가를 위한 폭로시험
Abstract
Sewage facilities mainly consisted of concrete structures are being deteriorated seriously by biodeterioration originated from sulfur-oxidizing bacteria. To prevent biochemical corrosion of the sewage concrete, antibiotics which prevent growth of sulfur-oxidizing bacteria were developed. Recently, to evaluate biochemical corrosion properties of concrete, antimicrobial performance and resistance to sulfuric acid were investigated respectively. But, in this study, to evaluate it complexly, concrete specimen covered with antibiotics were exposed in the actual sewage environment and were investigated about corrosion properties after three months. As a result, weight change ratio, nature potential and sulfuric ratio of concrete covered with antibiotics were less than plain concrete.
Keywords