An Exposure Experiment for the Evaluation of Corrosion Properties of Sewage Concrete Covered with Antibiotics

항균제를 도포한 하수시설 콘크리트의 생화학적 부식특성 평가를 위한 폭로시험

  • 노경민 (충남대학교 대학원 건축공학과) ;
  • 이의배 (충남대학교 대학원 건축공학과) ;
  • 김영덕 (충남대학교 대학원 건축공학과) ;
  • 이병기 ((주)트라이포드) ;
  • 김규용 (충남대학교 건축공학과) ;
  • 김무한 (충남대학교 건축공학과)
  • Published : 2006.05.11

Abstract

Sewage facilities mainly consisted of concrete structures are being deteriorated seriously by biodeterioration originated from sulfur-oxidizing bacteria. To prevent biochemical corrosion of the sewage concrete, antibiotics which prevent growth of sulfur-oxidizing bacteria were developed. Recently, to evaluate biochemical corrosion properties of concrete, antimicrobial performance and resistance to sulfuric acid were investigated respectively. But, in this study, to evaluate it complexly, concrete specimen covered with antibiotics were exposed in the actual sewage environment and were investigated about corrosion properties after three months. As a result, weight change ratio, nature potential and sulfuric ratio of concrete covered with antibiotics were less than plain concrete.

Keywords