Proceedings of the Korea Concrete Institute Conference (한국콘크리트학회:학술대회논문집)
- 2006.11a
- /
- Pages.693-696
- /
- 2006
Analysis and Measurements of Hydration Heat of Pile Cap of Approach Bridge in Incheon Bridge
인천대교 접속교 파일캡구조물의 수화열 해석 및 계측
- Published : 2006.11.04
Abstract
In massive hardening concrete structures, early age thermal cracking due to the heat of hydration may occur. There are many massive structures in Incheon bridge project and they have to be carefully treated to prevent thermal cracking. In this paper, an example of analyzed and measured results of hydration heat of pile caps in the Incheon bridge project was represented. Finite element simulations were carried out before casting and curing method was determined using the analyzed result. Sensors were installed before casting and temperature and strain of concrete was measured during curing. Gathered data were compared with the analyzed data and selected control method to prevent cracking was verified. Analyzed result gave good agreement and very few cracking could be found.
Keywords