Evaluation of Fire-Resistant Performance for Polypropylene Fiber-Mixed Mortar

폴리프로필렌 섬유 혼입 모르타르의 내화성능 평가

  • 이찬영 (한국도로공사 도로교통기술원) ;
  • 심재원 (한국도로공사 도로교통기술원) ;
  • 안태송 (한국도로공사 도로교통기술원) ;
  • 임채혁 (한국도로공사 도로교통기술원)
  • Published : 2006.11.04

Abstract

In this study, evaluation of fire-resistant performance for polypropylene fiber-mixed mortar was performed to establish specification for stability of tunnel structure against fire afterward. In the fire-resistant performance test with mix proportion of polypropylene fiber, cracks were observed for mortar under 0.15% of fiber content, but micro-cracks were remarkably reduced for mortar more than 0.2% of fiber content. From the results, we are concluded that optimal mix proportion of polypropylene fiber is $0.20{\sim}0.25%$.

Keywords