한국전기전자재료학회:학술대회논문집 (Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference)
- 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
- /
- Pages.5-7
- /
- 2006
PV모듈의 I-V특성 시험을 위한 Solar Simulator의 측정불확도 요인 분석
Analysis of Solar Simulator's Uncertainty Factor for Photovoltaic Module's I-V curve test
- 강기환 (한국에너지기술연구원 태양광발전연구단) ;
- 박지홍 (건국대학교 전기공학과) ;
- 김경수 (한국에너지기술연구원 태양광발전연구단) ;
- 유권종 (한국에너지기술연구원 태양광발전연구단) ;
- 안형근 (건국대학교 전기공학과) ;
- 한득영 (건국대학교 전기공학과)
- Kang, Gi-Hwan (Korea Institute of Energy Research) ;
- Park, Chi-Hong (Konkuk University) ;
- Kim, Kyung-Soo (Korea Institute of Energy Research) ;
- Yu, Gwon-Jong (Korea Institute of Energy Research) ;
- Ahn, Hyung-Keun (Konkuk University) ;
- Han, Deuk-Young (Konkuk University)
- 발행 : 2006.06.22
초록
In this paper, we analyzed the elements of measurement uncertainty on electrical performance test which are the most important things in photovoltaic module performance test. Repeating the performance test by 6 men, the measurement uncertainty could be calculated. In this experiment, Solar Simulator (A-Class pulse type) used for domestic certificate test of PV module is Pasan IIIb (Balval, Switzerland). The possible elements of the measurement uncertain that could effect electrical performance test of PV module are reference cell, spectrum correction, error from measurement repetition, test condition, stability and uniformity of artificial solar simulator. To find the measurement uncertainty, 6 men repeated the test by 10 times. And the results were that numerical average value was 124.44W and measurement uncertainty was