Precise response time measurement and analysis of liquid crystal displays

  • Published : 2006.08.22

Abstract

In this paper, we present a new system, OPTISCOPE SA, especially designed for precise measurement of temporal behavior of LCD displays. We show that gray to gray level response time measurement requires a very sensitive and precise instrument and also that the capacity to measure luminance levels and gamma curve can be useful. Quite often, precise evaluation of LCD response time needs also use of low pass and stop band filters to suppress noise and flicker. Low pass filters affect the results but can be corrected for simple temporal behaviors. For complex temporal behaviors like those observed for overdriven LCDs, we show that direct adjustment of theoretical responses is much more efficient to get a complete picture of the temporal behavior of such displays.

Keywords