Study on the corrosion of A/C condenser in the ship

선박용 해수 열교환방식 A/C 응축기의 부식원인

  • 백상민 (한국해양대학교 기관시스템공학부) ;
  • 양정현 (한국해양대학교 기관시스템공학부) ;
  • 김기준 (한국해양대학교 기관시스템공학부) ;
  • 문경만 (한국해양대학교 기관시스템공학부) ;
  • 이명훈 (한국해양대학교 기관시스템공학부)
  • Published : 2006.06.22

Abstract

The ship performs heat exchange using seawater to keep main engine and auxiliary machinery at optimum temperature. In heat exchanger, refrigerant located outside of copper tube is cooled by seawater flowing through inside of copper tube. On the other hand, seawater erosion and corrosion nay occasionally cause the corrosion of the copper tube in A/C(Air Conditioner) condenser. This corrosion of copper tube makes seawater and refrigerant mixed, seriously damaging A/C system. In this study, accordingly, the exact ive mechanism of the corrosion on the condenser entailing serious problems occasional is investigated through the electrochemical polarization experiments on the condenser's component materials. According to the experiments, the corrosive procedures on the copper tube was verified by the fact that passive film of the copper tube surface which is destroyed by the pressure of sucked seawater, is damaged by the corrosive ingredients in the seawater.

Keywords