초장대말뚝의 동재하시험 해석방안

A proposal for the analysis of the PDA testing results of the extra-long piles

  • 발행 : 2006.03.24

초록

These days the construction of extra-long piles increases. It is not unusual to install piles whose length exceed 45m. In such cases, the estimated value of negative skin friction becomes larger, often larger than the design load. In order to be sure of the safety of the super structure, the magnitude of the positive skin friction and the base bearing capacity should be known. In practice dynamic pile loading tests using PDA is the only possible measure to meet this requirement. However the analysis of dynamic pile loading test for such extra-long piles requires a thorough understanding of the pile-soil behaviour. In this paper, a new method to evaluate the positive skin friction and end bearing capacity from the normally performed PDA test is proposed. The proposed method was verified by performing specially designed pilot testings.

키워드