TFDR을 이용한 동측케이블의 다중 결함 측정

Multiple Fault Detection on a Coaxial Cable via TFDR

  • 곽기석 (연세대학교 전기전자공학과) ;
  • 윤태성 (창원대학교 전기공학과) ;
  • 박진배 (연세대학교 전기전자공학과) ;
  • 고재원 (유한대학 컴퓨터제어과)
  • Ki-Seok, Kwak (Department of Electrical and Electronic Engineering, Yonsei Univ.) ;
  • Yoon, Tae-Sung (Department of Electrical Engineering, Changwon National University) ;
  • Park, Jin-Bae (Department of Electrical and Electronic Engineering, Yonsei Univ.) ;
  • Koh, Jae-Won (Department of Computer Aided Control, Yuhan College)
  • 발행 : 2006.07.12

초록

In this paper, we considered multiple faults detection on a coaxial cable through Time-Frequency Domain Reflectometry (TFDR). It is well known that TFDR has high resolution accuracy for detecting and estimating the fault detection on a coaxial cable. This approach was based on time-frequency signal analysis and utilized a chirp signal multiplied by a Gaussian time envelope. The Gaussian envelope provided time localization, while the chirp allowed one to excite the system interest. We carried out experiments with 10C-FBT coaxial cable having either one or two faults. The result shows TFDR can be extended to detect multiple faults with high accuracy on a coaxial cable.

키워드