Compression tests were performed for six types of hat stiffened composite panels with different bonding methods and stiffener section shapes. Six panels showed similar behaviors in buckling and post-buckling region before a skin-stiffener separation failure occurred. The skin-stiffener separation failures occurred in the panels with closed type stiffeners regardless of bonding methods, but not in the panels with open type stiffeners. The separation failures not only reduced the postbuckling strength but also changed buckling mode and postbuckling stiffness. All the separation failures were initiated at the stiffener flange edges closest to skin buckling crests. The co-cured or secondary bonded panels with open type stiffeners had the largest structural performance. Because the post-buckling strength and performance of the composite stiffened panels are reduced by the separation failure, it is important to find bonding methods, stiffener types and manufacturing parameters for preventing of the separation failure.