Effect of Density on WCR Measurement of Water Content in Subgrade Soils

WCR을 이용한 노상토 함수량의 측정 및 밀도 영향 평가

  • 이치헌 (단국대학교 토목환경공학과) ;
  • 박성완 (단국대학교 토목환경공학과) ;
  • 정진훈 (한국도로공사 도로교통기술원) ;
  • 권순민 (한국도로공사 도로교통기술원)
  • Published : 2005.03.25

Abstract

The purpose of field monitoring system in KHC-Test Road located at Joongbu-Inland Highway, is to provide the performance data for traffic and environmental loadings from pavement surface. Among them, water content reflectometers(WCR) are used to measure the volumetric water content of subgrades soils used in test roads. However, most of the WCRs are not well-calibrated based on the field conditions. In this study, the laboratory based test is performed at various density conditions to evaluate the volumetric water content in subgrade Soils with a WCR. Based on the laboratory testings, the effect of density on WCR measurement are well evaluated for predicting the volumeric water content.of subgrades soils in KHC-Test road.