Seismic Response Tests of 1/8 Scale Model for a Spent Fuel Dry Storage Cask

사용후 연료 건식저장요기 1/8 규모 축소모형 지진응답시험

  • 이재한 (한국원자력연구소) ;
  • 구경희 (한국원자력연구소) ;
  • 서기석 (한국원자력연구소) ;
  • 이흥영 (한국수력원자력(주) 환경기술연구원) ;
  • 최병일 (한국수력원자력(주) 환경기술연구원) ;
  • 염성호 (충남대학교, 기계공학과)
  • Published : 2005.03.18

Abstract

The seismic response tests of a spent fuel dry storage cask model of 1/8 scale are performed for an typical 1940 Elcentro earthquake. This paper focuses on the seismic response test data generation to check the overturing possibility of a storage cask and the slipping displacement on concrete slab bed. A simplified cask model is used to take into account the variations in seismic load magnitude and cask/bed interface friction. The test results show that the model gives an overturning response for an extreme condition.