초록
Hydraulic conductivity of unconsolidated media can be determined by aquifer tests, laboratory tests and empirical equations based on grain size analysis. Commonly, the different methods give different hydraulic conductivities. Grain size measurements were done to determine hydraulic conductivity, using 184 soil samples collected from eight boreholes in a riverbank filtration area, Daesan-Myeon, Changwon City, Korea, Pumping tests were conducted at the riverbank filtration area. The average hydraulic conductivity by the empirical relations from grain size measurements comes out around