Indoor Environmental Condition by Existing Front Balcony in Apartment House during Winter

아파트의 전면발코니 개조여부에 따른 겨울철 실내환경 측정비교

  • 최윤정 (충북대학교 주거환경 소비자학과)
  • Published : 2005.05.28

Abstract

The purpose of this study was to make clear the indoor environmental efficiency of front balcony 'in apartment houses during winter. The field measurements of indoor environmental elements were carried out at an ordinary house with an existing front balcony and a house renovated the front balcony into the living room. The measurements in two-subject houses were taken on simultaneously the 20$^{th}$ ${\sim}$ 21$^{th}$ of January 2003. As results, the averages indoor temperature in the ordinary house and the renovated house were same as 23.6${\circ}$C, and the averages globe temperature in two houses were same as 23.7${\circ}$C. But, estimated heating time of the renovated house was longer than that of the ordinary house. The daily ranges of indoor temperature and globe temperature in the renovated house were wider than the ordinary house. The daily ranges of indoor temperature and globe temperature in the renovated house was longer than that of the ordinary house. The uniformity ratio range of daylight in the ordinary house were calculated at 1/3.4${\sim}$1/6.2, but those of the renovated house were 1/6${\sim}$1/16.2. Therefore. it was found that indoor temperature, globe temperature and uniformity ratio of daylight in the ordinary house maintained more constant than the renovated house by green house effect and earning effect of front balcony.