NPP I&C Architecture Design and Its Traffic Load Analysis

  • Published : 2005.05.14

Abstract

An integrated I&C architecture for nuclear power plants is designed by the systems and devices being developed in a project. Its design reference is the APR1400 that was design certified in Korea. Digital equipment and several kinds of data communication networks (DCN) are used. To confirm the validity of DCN based architecture design, the traffic loads fur each network were calculated assuming the anticipated maximum traffic condition. The analysis showed that the utilizations of all networks satisfied the design requirements.

Keywords