An Experimental Study III on the Bolted Connection between H-Beam and Precast-Concrete Column

PC 기둥-H형강보의 볼트접합부에관한 실험적 연구III

  • 여인석 (울산대학교 건축대학 대학원) ;
  • 박순규 (울산대학교 건축대학)
  • Published : 2005.11.01

Abstract

The PCS system, which consists of precast concrete column and steel beam, has been under development. Experimental test has been carried out to investigate the structural performance of the system under earthquake. Two types of test specimens of beam-column joints are designed in order to compare the performances. One is the system with reinforced concrete slab and the other is without slab. It is found that the system with slab could satisfy all of the requirements from ACI Criteria such as strength, stiffness degradation and energy dissipation capacity except initial stiffness. It is also investigated that the stiffness of the joint is belong to rigid joint type according to Bjorhovde criterion. And it is observed that the partial-composite system between beam and slab is more effective than full-composite system in the respect of the energy dissipation capacity of the system.

Keywords