Decontamination of Metal Surface by Reactive Cold Plasma

  • Published : 2005.11.01

Abstract

Recently plasma surface-cleaning or surface-etching techniques have been focused in the respect of decontamination of spent or used nuclear parts and equipment. In this study decontamination rate of metallic cobalt surface was experimentally investigated via its surface etching rate with a $CF_4-O_2$ mixed gas plasma and metallic surface wastes of cobalt oxides were simulated and decontaminated with $NF_3$ - Ar mixed gas plasma. Experimental results revealed that a mixed etchant gas with about $80{\%}\;CF_4-20{\%}\;O_2$ gives the highest reaction rate of cobalt disk and the rate reaches with a negative 300 DC bias voltage up to $0.43\;{\mu}m$/min at $380^{\circ}C$ and $20{\%}\;NF_3-80\%$ Ar mixed gas gives $0.2\;{\mu}m$/min of reaction rate of cobalt oxide film.

Keywords