한국조명전기설비학회:학술대회논문집 (Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference)
- 한국조명전기설비학회 2004년도 춘계학술대회 논문집
- /
- Pages.497-501
- /
- 2004
지중배전케이블 절연성능 향상 방안
The Improvement on Insulation Performance of Underground Distribution Power Cables
- 발행 : 2004.05.07
초록
The primary failure causes of underground distribution power cables are water penetration in insulation layer and stress enhancement at inner semi-conductive layer. Accordingly, it is needed to improve the materials and the structure of power cables for extending lifetime and preventing failure. We uses non-flaming PE materials instead of PVC as a covering material and encapsulating structure. We also use super smooth class material as a inner semi-conductive layer. The newly developed cables are improved in AC breakdown voltage after ageing tests.
키워드