부분방전 펄스파형에 대한 TF Map 적용 가능성애 대한 연구

A Study on the Applicability of TF Map for the Partial Discharge Pulse Shapes

  • 발행 : 2004.11.05

초록

It is well known that on-site corona and various noises make severe problems on the PD(partial discharge) measurement. In this paper, for the improvement of the on-site PD measuring performance, the applicability of TF(Time-Frequency) map was investigated. For the purpose, PDs that can be generated from the defect in the power cables as well as corona discharges and ground noises were measured. And through the TF analysis for the measured data, we have tried to distinguish the real PDs, corona discharges and noises. As a result, it is confirmed that the data of PDs can be clustered themselves separable from other data such as corona and noises on the TF map.

키워드