This study assesses groundwater vulnerability to contaminants in 12 administrative districts of the city of Changwon, using DRASTIC technique. DRASTIC was originally applied to situations in which the contamination sources are at the ground surface, and the contaminants flow into the groundwater with infiltration of rainfall. However, groundwater contamination in urban areas can also be related to excessive pumping resulting in a lowering of the water level. The correlation coefficient between minimum DRASTIC indices and the degree of poor water quality for 10 districts is low as 0.40. The correlation coefficients between minimum DRASTIC indices and the groundwater discharge rate, and between minimum DRASTIC indices and well density per unit area are 0.70 and 0.87, respectively. Thus, to evaluate the potential of groundwater contamination in urban areas, it is necessary to consider other factors such as groundwater withdrawal rate and well density per unit area with ratings and weights as well as the existing six DRASTIC factors.