Engineering-scale Test for Validating the T-H-M Behavior of a HLW Repository: Experimental Set-up

  • Published : 2004.06.01

Abstract

The thermo-hydro-mechanical (T-H-M) process is one of major issues in the performance assessment of a high level waste (HLW) repository. An engineering-scale test was planned and its experimental set-up has being installed, to validate the T-H-M behavior in the buffer of a reference disposal system. The experimental set-up consists of 4 major components: the confining cylinder with its hydration water tank, the bentonite block, the heating system, and the sensors and instruments. The monitoring and data acquisition system is employed to control the heater to maintain the temperature of $95^{\circ}C$ at the interface of the heater and bentonite blocks and to collect signals from sensors and instruments installed in the bentonite blocks.

Keywords