Electrolytic dissolution study was carried out to evaluate the applicability of electrochemical decontamination process using a neutral salt electrolyte as a decontamination technology for the recycle or self disposal with authorization of large amount of metallic wastes contaminated with uranium compounds generated by dismantling a retired uranium conversion plant using SUS-304 and Inconel-600 specimen as the main materials of internal system components of the plant. The effects of type of neutral salt as an electrolyte, current density, and concentration of electrolyte on the dissolution of the materials were evaluated. On the basis of the results obtained through the basic inactive experiments, electrochemical decontamination tests using the specimens contaminated with uranium compounds such as
국내의 가동 중지된 우라늄 변환시설의 해체 시 다량의 우라늄으로 오염되어 있는 금속성 폐기물의 재활용 또는 자체처분을 위한 제염기술로 중성염 전해액을 사용하는 전해제염 공정의 적용성을 평가하기 위하여 우라늄 변환시설 내부설비의 주 구성 재료인 SUS-304 및 Inconel-600에 대한 전기화학적 용해거동 연구를 수행하였다. 이를 위하여 중성염 전해질의 형태, 전해질의 농도, 전류밀도, 처리시간과 같은 전해제염 조건들이 금속 재료의 용해에 미치는 영향을 평가하였다. 모의 시편을 사용한 비방사성 전해용해 실험 결과를 근거로 실제 우라늄 변환시설로부터 인출한