Sensitivity Elevation about Spirometer Using Ultrasound Sensing Method

초음파 센싱 방식의 spirometer에 대한 sensitivity 향상

  • Published : 2004.05.01

Abstract

The respiration measurement method using the ultrasound sensor hardly gets an influence of an error of inertia and pressure and it is a respiratory detection device available semi-permanently. This device measures the amount and flow of respiration through using a delivery speed difference of the ultrasound waves that are a return format by the pneumatic stream that is a flogging of ultrasound waves during transmission and receipt as having used a characteristic of ultrasound waves. In this paper, it improved sensitivity of a signal to happen during transmission and receipt of a sensor because measurement must be performed with a patient to the center and measurement was played in a weak breathing so that it was possible.

초음파 센서를 이용한 호흡측정방식은 관성 및 압력의 오차의 영향을 거의 받지 않고, 반영구적으로 사용이 가능한 호흡기기이다. 초음파의 특성을 이용한 것으로 송수신시 초음파의 매질인 공기의 흐름에 의한 반송형식인 초음파의 전달속도 차이를 이용하여 호흡량 및 흐름을 detecting하는 기술이다. 본 논문에서는 환자를 중심으로 측정이 이루어져야 하기 때문에 센서의 송수신시 일어나는 신호의 sensitivity를 향상시켜서 약한 호흡에도 dectection이 가능하도록 하였다.